Why it matters
Heat stress cuts feed intake and milk output and can raise breeding problems. Temperature alone misleads, because high humidity limits a cow's ability to shed heat. THI combines both, and many extension programs flag stress beginning near THI 68 to 72, with severity rising from there. Thresholds vary by production level, so confirm yours with extension or your nutritionist.
Step by step
- Take the temperature in degrees C and relative humidity in percent from a thermometer and hygrometer at cow height in the barn, or from your nearest station.
- Compute THI = (1.8T + 32) minus (0.55 minus 0.0055 times RH) times (1.8T minus 26), with T in degrees C and RH in percent.
- Compare the result against your trigger levels from extension; write the numbers where the milking crew can see them.
- Turn on fans and soakers in holding pens and over feed lines at your first trigger, not after cows are panting heavily.
- Watch behavior: open-mouth breathing, drooling, standing crowded and lower feed intake all signal stress regardless of the calculated number.
- Shift feeding to cooler hours, keep clean water at every exit from the parlor, and discuss ration changes with your nutritionist.
Worked example
Illustrative: temperature 30C, humidity 50 percent. First, 1.8 times 30 plus 32 equals 86. Next, 0.55 minus 0.0055 times 50 equals 0.275. Then 1.8 times 30 minus 26 equals 28. Multiply 0.275 by 28 to get 7.7. THI is 86 minus 7.7, which equals 78.3. That is well above the 68 to 72 range where stress begins, so cooling should already be running.
Printable worksheet: THI calculation and response
- Date and time of reading: ____
- Temperature in C (convert from F: subtract 32, multiply by 5, divide by 9): ____
- Relative humidity percent: ____
- 1.8 times T plus 32: ____
- 0.55 minus 0.0055 times RH: ____
- 1.8 times T minus 26: ____
- THI result: ____
- My extension trigger levels (alert, stress, severe): ____
- Cooling actions started and time: ____
Common mistakes
- Using air temperature alone, which understates the load on cows during humid weather.
- Reading a station far from the barn, when the barn itself may run hotter and more humid.
- Forgetting to convert Fahrenheit to Celsius before using the formula.
- Starting fans only after cows are open-mouth breathing, when intake and milk are already falling.
Frequently asked questions
What THI is too high for dairy cows?
Many extension programs mark stress starting around THI 68 to 72, with moderate and severe levels higher. Exact thresholds depend on milk yield and adaptation, so check with your extension dairy specialist or nutritionist.
How do I calculate THI from Fahrenheit readings?
Convert temperature to Celsius first by subtracting 32, multiplying by 5 and dividing by 9. Then use THI = (1.8T + 32) minus (0.55 minus 0.0055 times RH) times (1.8T minus 26), with humidity as a percent.
Official sources
This guide is general planning education. Weather risk and rules vary by place; check current NWS products and your local extension office. Find your state resources.